USER'S GUIDE
Vaisala HUMICAP
®
Humidity and
Temperature Transmitters
HMD70U/Y
U303EN11
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - USER'S GUIDE

USER'S GUIDE Vaisala HUMICAP®Humidity and Temperature TransmittersHMD70U/Y U303EN11

Strany 2

HMD70U/Y TransmittersOperating Manual U303en-1.16 1997-07-313.4.1 Connection to an AC supplyThe HMD70U/Y transmitters can also be connected to an AC s

Strany 3 - Contents

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 73.5 Electronics10528HM18941HMGLANDS LIDSCREW TERMINALSCREWSMEMBRANE FILTER part no. 17039

Strany 4

HMD70U/Y TransmittersOperating Manual U303en-1.18 1997-07-314. CALIBRATION4.1 One-point humidity calibrationThe accuracy is recommended to be checked

Strany 5 - 1. PRODUCT DESCRIPTION

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 94.3 Calibration tableTemperature °C 15 20 25 30 35°F 59 68 77 86 95LiCl %RH *) 11.3 11.3 1

Strany 6 - 2 1997-07-31

HMD70U/Y TransmittersOperating Manual U303en-1.110 1997-07-316. TECHNICAL DATA6.1 Relative humidityMeasurement range 0...100 %RHAccuracy at 20 °C:10 4

Strany 7 - 3. INSTALLATION

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 116.3 GeneralSupply voltage range depends on the selected output signal.When AC supply is u

Strany 8 - 4 1997-07-31

HMD70U/Y TransmittersOperating Manual U303en-1.112 1997-07-316.4 Electromagnetic compatibilityThe emission and immunity tests have been performed acco

Strany 11 - 3.5 Electronics

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at ht

Strany 12 - 4. CALIBRATION

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 iContents1. PRODUCT DESCRIPTION ...

Strany 13 - 5. MAINTENANCE

HMD70U/Y TransmittersOperating Manual U303en-1.1ii 1997-07-31This page intentionally left blank.

Strany 14 - 6. TECHNICAL DATA

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 11. PRODUCT DESCRIPTIONThe HMD70 transmitters are duct mounted three-wire transmitters for

Strany 15

HMD70U/Y TransmittersOperating Manual U303en-1.12 1997-07-312. TO BE NOTED WHEN MEASURING HUMIDITYIn the measurement of humidity and especially in cal

Strany 16 - 12 1997-07-31

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 33. INSTALLATION3.1 Selecting the place of installationSelect a place that gives a true pic

Strany 17

HMD70U/Y TransmittersOperating Manual U303en-1.14 1997-07-313.3 GroundingOpen the lid and mount the cable bushing set 18941HM. Do the groundingaccordi

Strany 18

HMD70U/Y TransmittersU303en-1.1 Operating Manual1997-07-31 53.4 Electrical connections and installation of the current moduleFigure 3.4 shows the elec