DMT345 and DMT346 Dewpoint Transmitters
for High Temperature Applications
The Vaisala DRYCAP
®
Dewpoint
Transmitters DMT345 and
DMT346 are designed for humidity
measurement in industrial drying
applications with particularly high
temperatures.
Both transmitters incorporate the
Vaisala DRYCAP
®
sensor, which is
accurate, reliable, and stable. The
sensor is condensation-resistant
and is immune to particulate
contamination, oil vapor, and most
chemicals. The DRYCAP
®
sensor is
notable for its swift response time
and rapid recovery after getting wet.
Measure Humidity Directly
in Hot Processes
The DMT345 and DMT346 are
built for direct measurement in
hot processes. Therefore, there
is no need for sampling systems
and trace heating. As a result,
high measurement accuracy and
constancy are maintained.
Vaisala DRYCAP
®
Dewpoint Transmitters DMT345 and DMT346 are designed
to measure and control humidity, especially in dry environments with high
temperatures.
The accuracy and stability of the
DMT345 and the DMT346 are due to
their unique auto-calibration function,
developed by Vaisala. This feature
allows the transmitter to perform
calibration and adjustment by itself
while the measured process is
running. If the measurement accuracy
is not confirmed, corrections are
made automatically. The procedure
is so quick and corrections so
minor that it causes no disruption,
ensuring easy maintenance and high
performance. In normal conditions, it
is recommended to have a traceable
calibration performed once a year.
DMT345: Accurate in Hot
and Dry Environments
The DMT345 is designed for accurate
humidity measurement in hot and
dry conditions. This model provides
unmatched dry-end measurement
accuracy at temperatures up to 140°C;
however, it can operate safely at
temperatures up to 180 °C.
Features/Benefits
The DMT345 measures
humidity at temperatures up to
180 °C (356 °F)
The DMT346 measures
humidity at temperatures up to
350 °C (+662 °F)
Dew point accuracy ±2 °C
(±3.6 °F)
Vaisala DRYCAP® sensor
provides accurate and reliable
measurement with excellent
long-term stability and fast
response time
Condensation-resistant
Unique auto-calibration feature
NIST traceable calibration
(certificate included)
Graphical display and keypad
for convenient operation
Optional alarm relays and
mains power supply module
Analog outputs, RS232/485,
WLAN/LAN
MODBUS protocol support
(RTU/TCP)
The large graphical display allows the
user to check data at a glance.
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - DMT345: Accurate in Hot

www.vaisala.comDMT345 and DMT346 Dewpoint Transmitters for High Temperature ApplicationsThe Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 ar

Strany 2 - Technical Data

Technical DataMeasured Variables DMT345DEW POINT DMT345Sensor Vaisala DRYCAP®180SMeasurement range -40 ... +100 °C (-40 ... +212 °F) TdAccuracy ±2°C (

Strany 3

Technical DataOperating Environment, DMT345 and DMT346 Mechanical durability up to +180 °C (+356 °F) for DMT345of probes up to +350 °C (+662 °F) for D

Strany 4 - Please contact us at

Technical DataDimensionsDimensions in mm (inches)DMT345 and DMT346 transmitter housingDRYCAP® is a registered trademark of Vaisala.169 (6.65)116 (4.57