116 117
GML20 and GML20T
LonWorks® Options for GMD/W20 Series
Significant savings
Vaisala's GML20 and GML20T are
interface modules for distributing
signals from Vaisala CARBOCAP
®
Carbon Dioxide Transmitter Series
GM20 digitally to a LonWorks
®
network over a twisted pair.
GML20T module connects a Vaisala CARBOCAP
®
Carbon Dioxide Transmitter
GMW21 to a LonWorks
®
network.
The GML20 Module distributes
CO
2
signals; the GML20T Module
distributes both CO
2
and temperature
signals. The GML20T Module can
be used only with the Vaisala
CARBOCAP
®
Carbon Dioxide
Transmitter GMW21.
The use of these modules and
Vaisala CARBOCAP
®
Carbon Dioxide
Transmitter Series GM20 with a
LonWorks
®
networked control
system contributes to considerable
savings in cabling, installation and
maintenance costs.
Intelligent LonTalk®
protocol
In a LonWorks
®
network, devices
called nodes communicate with each
other using the LonTalk
®
protocol.
Every node consists of a Neuron
®
Features/Benefits
Enables digital communication
between Vaisala CARBOCAP®
Carbon Dioxide Transmitter
Series GM20 and LonWorks®
GML20 for CO
2
signal
GML20T for CO
2
+ T signal
Savings in cabling, installation
and maintenance costs
GML20 (left) and GML20T modules
enable digital communication between
the Vaisala CARBOCAP
®
Carbon
Dioxide Transmitter Series GM20 and a
LonWorks
®
network.
chip and a transceiver. The Neuron
®
chip is a microprocessor which
contains an application program and
LonTalk
®
protocol. The transceiver
adapts the Neuron
®
chip into the
hardware environment used. The
nodes communicate with each other,
sending messages containing the
value of the desired variables.
With Vaisala modules, these
variables are CO
2
(GML20) or CO
2
and temperature (GML20T). Some
network variables are so-called
conguration variables, which are
used to dene the behavior of the
node. With the GML20 and GML20T,
they are used to designate how much
the temperature and/or carbon
dioxide level must change before a
measured value is sent again.
Technical data
Features
t -PO8PSLT
®
interoperable
t 5XJTUFEQBJSGSFFUPQPMPHZOFUXPSLUZQF51'5BULCQT
t "EEJUJPOBMUXPXJSFTOFFEFEGPSQPXFSJOHUIFUSBOTNJUUFSDBO
thus be connected to both powered and non-powered networks
t 4FSWJDFCVUUPOBOETFSWJDF-&%GPSTJNQMFJOTUBMMBUJPOBOE
configuration
t &YUFSOBMJOUFSGBDFYJGGJMFBWBJMBCMFPOSFRVFTU(.-
part no. 19412GM, GML20T part no. 19748GM)
t 5FNQFSBUVSF(.-5POMZ.FBTVSFNFOUBDDVSBDZ
0.5 °C (0.9 °F) Measurement range 0 ... +45 °C (+32 ... 113 °F)
Warm-up time 30 min.
Network Variables for CO
2
(BOTH MODELS GML20 AND GML20T)
nviRequest: to request modes for objects within this node
nvoStatus: to report status of objects on this node
nvoCO
2
ppm: this output variable reports the CO
2
level detected by
the sensor
nciMaxSendtime: indicates the maximum period of time that
expires before the sensor object automatically updates all its
output variables (default value: 300 seconds)
nciMinSendtime: indicates the minimum period between output
network variable transitions (default value: 5 seconds)
nciCO
2
MinDelta: indicates the minimum CO
2
level change
required to update the output network variables
(default value: 10 ppm)
LonWorks
®
is a registered trademark of Echelon Corporation.
Networks Variables for Temperature
(GML20T MODEL ONLY)
nvoHVACtemp: this output variable reports the temperature
detected by the sensor
nciMaxStime_temp: indicates the maximum period of time that
expires before the sensor object automatically updates all its
output variables (default value: 300 seconds)
nciMinStime_temp: indicates the minimum period between
output network variable transitions (default value: 5 seconds)
nciMinDelta_temp: indicates the minimum temperature change
required to update the output network variables
(default value: 0.3 °C)
nciTmpOffset: indicates the temperature offset level
(default value: -0.8 °C)
Ref. B210943EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Zobrazit stránku 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 122 123

Komentáře k této Příručce

Žádné komentáře