Configurable Parameters
Table 67 below lists the configurable parameters and their
allowed and default values for the WMT700 NMEA MWV
profile.
Table 67 Configurable Parameters for WMT700 NMEA
MWV Profile
Profile-Specific Allowed
Values
String with 2 characters,
for example "WI"
Address for WMT700. The address must
consist of two capital letters A … Z
Resolution: 0.25
Automatic message interval in seconds.
Do not select a message interval that is
shorter than the time it takes to send a data
1 = COM1 port
2 = COM2 port
Serial port to which WMT700 sends
automatic data messages
disabled
20 = WMT700 NMEA
MWV automatic data
Automatic data message number. Selects
the data message format for automatic
messages
11 = WMT700 NMEA
MWV protocol
Profile for serial port COM1
11 = WMT700 NMEA
MWV protocol
Profile for serial port COM2
1 = RS-422
Interface for serial port COM2
0.25 … 3600
Resolution: 0.25
Averaging time for wind measurement in
seconds
0 = Array facing up
1 = Array facing down
Orientation of the array of WMT700
1 = Miles per hour
2 = Kilometers per hour
* COM1 service port is always by default 0 - WMT700 protocol. This can be
changed using serial commands if COM1 is needed for protocol-specific
communication.
** Wind speed unit and COM2 digital communication interface are defined in
the order form. Default setting may be any of the allowed options, and it can be
verified from the unit's configuration code.
To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to sections START — Start Continuous
Measurement and STOP — Stop Wind Measurement on page
115.