User's Guide ______________________________________________________________________
RS485 Cable 2 m and RS485 Cable
10 m
RS485 Cable 2 m and RS485 Cable 10 m are designed for the
standard connection: operating power, heater power, and RS485.
The two-wire RS485 loopback connections, as shown in Table 24
below, are preconnected inside the cable.
Table 24 Connecting RS485 Cable 2 m (228259SP) and
RS485 Cable 10 m (228260SP)
Power Supply
Wire Colors
Pin
Operating Power Supply
White
1
Operating Power Supply Ground
Gray-Pink
11
Heater Power Supply
Gray, Green, Pink
5, 6
Heater Power Supply Ground
Blue, Black, Red, Yellow
7, 8
Enclosure Ground
Shield
Shield
COM2
RS485 -
Brown
3,4
RS485 +
Red-Blue
14, 15
Communications Ground
Violet
10