Vaisala WMS302 Uživatelská příručka Strana 194

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 262
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 193
User's Guide ______________________________________________________________________
192 __________________________________________________________________M210630EN-B
Resetting MAWS
To reset MAWS, give the command reset (recommended) or press the
reset button, see number 1 in Figure 138 on page 155.
0406-060
Figure 148 Reset Button on Logger
A short reset (pressing the reset button quickly) performs the same reset
as giving the command and starts the program again. A long reset
(pressing the reset button and keeping it down for a few seconds)
restarts the program with a so-called blank setup. A blank setup does not
run a configuration file.
Blank setup may be useful if the configuration is somehow defective
and does not allow the user to open a terminal connection. When the
blank setup is run, MAWS communication parameters are restored to
their defaults: COM0, 9600, N, 8, N, 1.
Determining Sensor Status
Sensor status values give indication about the general status of the
sensor interfaces. You have two alternatives to view the status value for
a sensor:
NOTE
Sensors with their own measurement interfaces and algorithms, for
example Vaisala Ceilometer or Vaisala Present Weather Detector, do
not appear in the sensor list of the Sensor Calibration tab.
Zobrazit stránku 193
1 2 ... 189 190 191 192 193 194 195 196 197 198 199 ... 261 262

Komentáře k této Příručce

Žádné komentáře