Chapter 4 _______________________________________________________________ Installation
VAISALA_______________________________________________________________________ 79
Rain Gauges
Installation Procedure of QMR101
Usually, rain gauge QMR101 is installed on the same sensor arm with
the temperature and humidity probe. QMR101 should be attached to a
sensor arm in the following way:
1. Attach the mounting plates (1) to the sensor (2), if not already in
place.
9806-062
Figure 64 Mounting Plates Attachment
2. Attach the rain gauge (1) to the arm with the screws (2) provided
with the rain gauge.
9901-010
Figure 65 Rain Gauge Attachment
Installation Procedure of QMR102
Rain gauge QMR102 can be installed on the ground, on a base plate, or
on a separate stand near the logger. Due to the low weight of the rain
gauge, it must be mounted securely. QMR102 can be installed either
using a specific stand RG35003 or on the ground when it is attached to
a properly anchored RGB1 base plate with provided studs. As well, the
Zobrazit stránku 80