CHAPTER 3_______________________________________________________________INSTALLATION
VAISALA _________________________________________________________________________ 23
Connections
V
mA
+
-
CH1+
CH1-
CH2
CH2 -
24 V +
X2
X1
V
mA
+
-
CH1- and CH2- are connected
together internally
CURRENT/VOLTAGE
OUTPUTS
(INTERNAL OR
EXTERNAL)
Do not use power supply
ground (-) as output signal
ground
OPENED COVER OF THE DMP248
FIGURE 3-18 Electrical connections
Power supply 24 VDC
24 VAC (see Chapter Connection
to an AC supply)
Output signals 0...20 mA
4...20 mA
0...1 V
0...5 V
0...10 V
Power supply ground (-) is connected to the housing with parallel
connection of 15 nF capacitor and 300 kΩ resistor.