Chapter 7 ____________________________________________________________ Technical Data
VAISALA ______________________________________________________________________ 155
Data Logger Module
Operating temperature range -40 ... +60 ºC (-40 ... +140 ºF)
Storage temperature range -55 ... +80 ºC (-67 ... +176 ºF)
Power consumption @ 24V max 10 mA
Logged parameters up to three with trend/min/max
values for each
Logging interval 10 s (fixed)
Maximum logging period 4 years 5 months
Logged points 13.7 million points / parameter
Accuracy of the clock better than ±2 min/year
Battery lifetime
at -40 ... +30 ºC (-40 ... +86 ºF) 7 years
at +30 ... +60 ºC (+86 ... +140 ºF) 5 years
Options and Accessories
Description Item code
MODULES
Relay Module RELAY-1
Analog Output Module AOUT-1
Isolated RS485 Module RS485-1
Power Supply Module POWER-1
Galvanic Isolation Module DCDC-1
SENSORS
HUMICAP180 HUMICAP180
HUMICAP180R HUMICAP180R
PT100 Sensor 10429SP
FILTERS
PPS Plastic Grid with Stainless Steel
Netting
DRW010281SP
PPS Plastic Grid Filter DRW010276SP
Sintered Filter AISI 316L HM47280SP
Stainless Steel Filter HM47453SP
Stainless Steel Filter with Membrane 214848SP
TRANSMITTER MOUNTING ACCESSORIES
Wall Mounting Kit 214829
Probe Holder Plate 226252
Installation Kit for Pole or Pipeline 215108
Rain Shield with Installation Kit 215109
DIN Rail Clips with
Installation Plate
215094
Meteorological Installation Kit HMT330MIK
Panel Mounting Frame 216038
PROBE MOUNTING ACCESSORIES
HMT334
Fitting Body M22x1.5 17223SP
Fitting Body NPT1/2 17225SP
HMT335
Mounting Flange For HMT335 210696
HMT337
Swagelok for 12mm Probe 3/8" ISO
Thread
SWG12ISO38
Swagelok for 12mm Probe 1/2" ISO
Thread
SWG12ISO12